e-Elit - juhtiv
elektri- ja automaatikatarvikute
online hulgimüük
Klienditeenindus E-R 9-17
Helista: +372 622 9119
Est En
Elit shopping basket
Tooteid: Maksumus:
0
€ 0,00
    search
Logi sisse
Kasutajatunnus/e-post:

Parool:

Näita kõiki kategooriaid
Ei leidnud sobilikku toodet?
Head pakkumised!
PE-riviklemm A2C 16 PE, 1-tier, 16mm² 1000V, push-in, koro
PE-riviklemm A2C 16 PE, 1-tier, 16mm² 1000V, push-in, koro



Sagedusmuundur PowerFlex400, 11kW 22A 3x480VAC, integral keypad, LED display, RS485, frame C, Allen-Bradley
Pilt on illustreeriv
Sagedusmuundur PowerFlex400, 11kW 22A 3x480VAC, integral keypad, LED display, RS485, frame C, Allen-Bradley
Kood: 22C-D022N103
Hind (indikatiivne)
€ 980,00  /tk
Tootja :
Saadavus:
küsi tarneaega
Kaal:
7.3 kg/tk
Maht:
0.0266 m3/tk
Kogus (tk):
Plus sign Minus sign
 

 

AC Drive PowerFlex400, 11kW 22A 3x480VAC, integral keypad?LED display, RS485, frame C, Allen-Bradley

DESCRIPTIONS
PowerFlex®400 Air Cooled Drive, Voltage Rating: Input: 308 - 480 V, Output: 480 VAC, Amperage Rating: 22 A, Wattage: 11 KW, Phase: 3 PH, HP Rating: 15 HP, Frame Size: Size C, Frequency Rating: 50/60 HZ, Power Factor: 0.98, Control: RS-485, Mounting: Panel, Display: Integral Keypad And LED, Connection: Fixed Terminal, Enclosure: IP20, Open Type, Environmental Conditions: Altitude: 1000 M (3300 FT) max. without derating. Above 1000 M (3300 FT) derate 3% for every 305 M (1000 FT), Air Temperature: -10 To 50 DEG C, Storage Temperature: -40 To 85 DEG C, Relative Humidity: 0 - 95%, Shock (Operating): 15G Peak For 11 MS Duration, Vibration (Operating): 1G Peak, 5 - 2000 HZ, Dimension: 10.2 IN Height X 5.1 IN Width X 7.1 IN Depth
SPECIFICATIONS
  • Item Name: Air Cooled Drive

  • Sub Brand: PowerFlex®400

  • Voltage Rating: Input: 308 - 480 V, Output: 480 VAC

  • Amperage Rating: 22 A

  • Wattage: 11 KW

  • Phase: 3 PH

  • HP Rating: 15 HP

  • Frame Size: Size C

  • Frequency Rating: 50/60 HZ

  • Power Factor: 0.98

  • Control: RS-485

  • Mounting: Panel

  • Display: Integral Keypad And LED

  • Connection: Fixed Terminal

  • Enclosure: IP20, Open Type

  • Environmental Conditions: Altitude: 1000 M (3300 FT) max. without derating. Above 1000 M (3300 FT) derate 3% for every 305 M (1000 FT), Air Temperature: -10 To 50 DEG C, Storage Temperature: -40 To 85 DEG C, Relative Humidity: 0 - 95%, Shock (Operating): 15G Peak For 11 MS Duration, Vibration (Operating): 1G Peak, 5 - 2000 HZ

  • Dimension: 10.2 IN Height X 5.1 IN Width X 7.1 IN Depth

FEATURES
  • Built in auxiliary motor control
  • Operation of up to three (3) line-started motors in addition to the motor controlled directly by the PowerFlex 400 drive
  • When auxiliary motor control is enabled, the internal PID controller in the PowerFlex 400 uses a reference and feedback signal to adjust the speed of the drive controlled motor such that the feedback signal follows the reference signal
  • The speed of the drive controlled motor is reduced to account for the auxiliary motors additional output to the system
  • A motor interlock input identifies motors that are out of service and causes them to skipped over to the next available motor
  • AutoSwap function also can be used which allows equal wear to be placed on each motor by periodically swapping the drive controlled and auxiliary motors
  • Each motor in the system will over time be connected to the PowerFlex 400 drive and also directly to the AC line
  • During an autoswap, the motor directly connected to the PowerFlex 400 drive is stopped and the contactor is opened
  • The contactor of the next motor that will be controlled by the PowerFlex 400 drive is opened if running across the AC line
  • Without filtered emission class
  • Drive has an input which can be wired to a fire control panel or other fire/life safety systems allowing control of the drive to be overridden
  • A purge input will start the drive at a programmable purge speed regardless of the selected start source, purge can occur and is operational at any time whether the drive is running or stopped
  • A purge command will take precedence over a stop command from the comm port/network and over a “SW Enable” command from the terminal block
  • Standards: Listed to UL508C and CAN/CSA-22.2, listed to UL508C for plenums, certified to AS/NZS, 1997 group 1, class A, EMC directive (89/336) EN 61800-3, EN 50081-1, EN 50082-2, EN 50178, EN 60204
 
 